| 902D Headspace Analyzer
902D Headspace Analyzer This headspace analyzer contains an internal pump to draw in sample from your package and display O2 and CO2 concentration results in 30 seconds. The expected oxygen sensor life is typically 5 years, unlike other analyzers with a sensor that last 1-2 years, reducing total cost of ownership, and analyzer downtime. Specifications racy - Carbon Dioxide Accuracy (for 0-100% range) ± 1% of reading, or ± 0.2% CO2 (whichever is greater), Accuracy (for 0-20% range) ± 1% of reading or ± 0.1% CO2 (whichever is greater) CO2 Minimum Detection Limit 0.1% (0-100% range) or 0.01% (0-20% range) CO2 Calibration Controls Potentiometer SPAN adjustment for CO2. CO2 Calibration Frequency Every 12 months; calibration gas recommended. Oxygen Range 0.0 to 100% Oxygen Sensitivity 0.1% O2 O2 Resolution 0.1% O2 (optional .01%) Analog Output Not Available Accuracy : +/- 1% of reading; +/- 0.1% absolute below 10.0% Drift less than 0.4% per year Oxygen Sensor Type Proprietary Electrochemical Response Time 25 seconds to T95 O2 Sensor Lifetime 4-5 Years O2 Sensor Body ABS Resin Sample Connection Sample Probe Sample Method Pump Sample Pump Miniature diaphragm type with ~5cc/sec flow Pump Timing 2-12 second adjustable pump time, potentiometer on back of analyzer Minimum Sample Required 15cc Sampling Assembly Probe with female luer connection for filter and needle, low volume PTFE tubing Oxygen Calibration Controls SPAN adjustment, zero adjustment Instrument Calibration Calibrates with room air; coarse SPAN adjustment on back; fine span adjustment on side; ZERO adjustment on side (calibration gas recommended for CO2) Exhaust port Vents to air Power Supply 100-240V (50-60Hz) Charger included, with US or international interchangeable plug adapter (upon request) Backup Power Optional 12V internal battery pack Battery Operation Optional Input Voltage 100-240V, 50-60Hz Battery Life 8-12 hours before recharging Measures: O2, CO2 O2, CO2 Form Factor Benchtop Size 9.8W x 4H x 10L in. (249 x 102 x 254 mm) Weight 9.8 lb. (4.4 Kg) Standards CE, RoHS Included Consumables 200 foam septas, 2 luer fit needles, 2 particulate filters, 2 liquid block filters Options Battery, 0.01% resolution for O2 Included Documentation Owners manual (includes operating instructions with detailed calibration instructions, calibration certficate, precautions), NIST calibration certificate Origin of Goods Our products are manufactured in the U.S.A. Products by Gas Oxygen and CO2
Products by Applications Headspace / Package
|

