| ตู้ควบคุมอุณหภูมิและความชื้น Memmert SF110
Code:PT 008 Memmert SF110 Temperature and Humidity Control Cabinet An essential safety feature for hot air sterilizers is Setpoint Wait, which means the sterilization program will only start when the set temperature is reached. This feature can be used with a freely positioned Pt100 temperature sensor. Here, the sterilization time will only start when the set temperature is reached at all measurement points, ensuring reliable sterilization at all times. Temperature - Settable temperature range: +20 to +250°C - Temperature setting accuracy: Up to 99.9°C: 0.1°C / From 100°C: 0.5°C - Operating temperature range: At least 10°C above ambient temperature to +250°C - Temperature sensor: One Pt100 sensor, DIN Class A, in a 4-wire circuit Control technology - Language setting: German, English, Spanish, French, Polish, Czech, Hungarian - ControlCOCKPIT: SingleDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with high-definition TFT-colour display - Timer: Digital backwards counter with target time setting, adjustable from 1 minute to 99 days - Function SetpointWAIT: the process time does not start until the set temperature is reached - Calibration: three freely selectable temperature values adjustable parameters: temperature (Celsius or Fahrenheit), fan speed, air flap position, programme time, time zones, summertime/wintertime Ventilation Fan: forced air circulation by quiet air turbine, adjustable in 10 % steps Fresh air: Admixture of pre-heated fresh air by electronically adjustable air flap Vent: vent connection with restrictor flap Communication Documentation: programme stored in case of power failure Programming: AtmoCONTROL software for reading out, managing and organising the data logger via Ethernet interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software available as accessory (on demand). Safety Temperature control: adjustable electronic overtemperature monitor and mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 20°C above nominal temperature Autodiagnostic system: for fault analysis Standard equipment Works calibration certificate: Calibration at +160°C Door: fully insulated stainless steel door with 2-point locking (compression door lock) Internals: 2 stainless steel grid(s), electropolished Stainless steel interior Dimensions: w(A) x h(B) x d(C): 560 x 480 x 400 mm (d less 39 mm for fan) Interior: easy-to-clean interior,made of stainless steel, reinforced by deep drawn ribbing with integrated and protected large-area heating on four sides Volume: 108 Max. number of internals: 5 Max. loading of chamber: 175 kg Max. loading per internal: 20 kg Textured stainless steel casing Dimensions: w(D) x h(E) x d(F): 745 x 864 x 584 mm (d +56mm door handle) Housing: rear zinc-plated steel Electrical data Voltage Electrical load: 230 V, 50/60 Hz approx. 2800 W Voltage Electrical load: 115 V, 50/60 Hz approx. 1800 W Ambient conditions Set Up: The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Altitude of installation: max. 2,000 m above sea level Ambient temperature: +5 °C to +40 °C Humidity rh: max. 80 %, non-condensing Standard units are safety-approved and bear the test marks
|